Rheonik – RHE 28

Kontakt os

Udfyld formularen, så vender vi retur hurtigst muligt. Du kan forvente at høre fra os inden for 2 arbejdsdage. Hvis dit behov er akut, anbefaler vi, at du ringer til os på 8689 0488.

Accepter brug af persondata

* = obligatoriske Privatlivspolitik

Rheonik – RHE 28

Avanceret Coriolis-transmitter i epoxybelagt aluminiumskabinet. Designet til universel feltmontering og præcis flowmåling i krævende industrielle applikationer, herunder farlige områder.

For yderligere information om produkterne, kontakt Rasmus Kjærgaard Rossen på tlf. 31 17 16 15

Rheonik RHE 28 er en transmitter til signalbehandling af data fra Rheoniks Coriolis-sensorer. Enheden er designet til universel feltmontering og leveres i et robust, epoxybelagt aluminiumskabinet, der beskytter mod industrielle ydre påvirkninger og vejrforhold.

GENERELLE EGENSKABER

Housing:

Epoxy coated cast aluminum universal field mount enclosure

Enclosure Rating:

IP65 / NEMA 4.  Optionally IP66 / NEMA 4

Ambient Temperature:

-20°C (optionally -40°C) to +60°C / -4°F (-40°F) to +140°F

(reduced visibility below -20°C)

Dimensions:

170 x 272 x 93 mm / 6.7 x 10.7 x 3.7 in

Display:

Large high contrast backlit LCD 128 x 24. Screen changes color to indicate warning or error

Weight:

2.4 kg / 5.3 lb

Operation:

3 x behind-window capacitive sensors for menu navigation / settings

Sensor Connection:

Cage clamp terminals.  Cable available in lengths up to 100m for connection to remote sensor

Analog Outputs:

Up to 2 x 4-20mA outputs, active or passive, compl. to NAMUR NE-43

Digital Outputs:

Up to 2 x configurable status outputs (IEC60946)

Pulse/Frequency Output:

Up to 2 x configurable pulse/frequ. outputs (IEC60946), max 10 kHz

Digital Inputs:

Up to 2 x configurable control inputs (to IEC60946)

Analog Input (optional):

1 x 4-20mA analog input (active) for two-wire pressure or density sensor

Power Supply:

100-240 VAC +/- 10%  (48 to 62 Hz), 5W or 12-24 VDC +/- 10%, 4W

Digital Data Communications:

Modbus RTU (RS485)
Connection to PC (USB) with Rheonik RHECom software
HART over analog output

Hazardous Area Approvals:

ATEX/IECEx for RHE in ordinary locations (code AS), RHM in all zones

ATEX/IECEx for RHE in zone 2 (code AB, A2), RHM in all zones

cCSAus for RHE in ordinary locations (code CS), RHM in all divisions cCSAus for RHE in Div. 2 (code CB, C2), RHM in all divisions

Cable Entries:

2 x M16, 2 x M20 as standard

Download datablad

Søg efter produkter

Generic filters

Kontakt

For yderligere information kontakt Rasmus Kjærgaard Rossen på tlf. 31 17 16 15

TILMELD DIG TIL VORES NYHEDSBREV

Du kan her tilmelde dig vores nyhedsbrev som med jævne mellemrum udsendes (6-8 gange årligt).
På den måde vil du blive opdateret på nye produkter, applikationseksempler samt andet relevant fra HH Instruments A/S.