Rheonik RHE 28 er en transmitter til signalbehandling af data fra Rheoniks Coriolis-sensorer. Enheden er designet til universel feltmontering og leveres i et robust, epoxybelagt aluminiumskabinet, der beskytter mod industrielle ydre påvirkninger og vejrforhold.
GENERELLE EGENSKABER
Housing: | Epoxy coated cast aluminum universal field mount enclosure |
Enclosure Rating: | IP65 / NEMA 4. Optionally IP66 / NEMA 4 |
Ambient Temperature: | -20°C (optionally -40°C) to +60°C / -4°F (-40°F) to +140°F (reduced visibility below -20°C) |
Dimensions: | 170 x 272 x 93 mm / 6.7 x 10.7 x 3.7 in |
Display: | Large high contrast backlit LCD 128 x 24. Screen changes color to indicate warning or error |
Weight: | 2.4 kg / 5.3 lb |
Operation: | 3 x behind-window capacitive sensors for menu navigation / settings |
Sensor Connection: | Cage clamp terminals. Cable available in lengths up to 100m for connection to remote sensor |
Analog Outputs: | Up to 2 x 4-20mA outputs, active or passive, compl. to NAMUR NE-43 |
Digital Outputs: | Up to 2 x configurable status outputs (IEC60946) |
Pulse/Frequency Output: | Up to 2 x configurable pulse/frequ. outputs (IEC60946), max 10 kHz |
Digital Inputs: | Up to 2 x configurable control inputs (to IEC60946) |
Analog Input (optional): | 1 x 4-20mA analog input (active) for two-wire pressure or density sensor |
Power Supply: | 100-240 VAC +/- 10% (48 to 62 Hz), 5W or 12-24 VDC +/- 10%, 4W |
Digital Data Communications: | Modbus RTU (RS485) |
Hazardous Area Approvals: | ATEX/IECEx for RHE in ordinary locations (code AS), RHM in all zones ATEX/IECEx for RHE in zone 2 (code AB, A2), RHM in all zones cCSAus for RHE in ordinary locations (code CS), RHM in all divisions cCSAus for RHE in Div. 2 (code CB, C2), RHM in all divisions |
Cable Entries: | 2 x M16, 2 x M20 as standard |
Download datablad
Søg efter produkter
Kontakt
For yderligere information kontakt Rasmus Kjærgaard Rossen på tlf. 31 17 16 15
TILMELD DIG TIL VORES NYHEDSBREV
Du kan her tilmelde dig vores nyhedsbrev som med jævne mellemrum udsendes (6-8 gange årligt).
På den måde vil du blive opdateret på nye produkter, applikationseksempler samt andet relevant fra HH Instruments A/S.